{"product_id":"beautivana-9-in-1-professional-face-body-beauty-system-multifunctional-spa-machine","title":"Beautivana 9-in-1 Professional Face \u0026 Body Beauty System – Multifunctional Spa Machine","description":"\u003ch2\u003eBeautivana 9-in-1 Professional Face \u0026amp; Body Beauty System\u003c\/h2\u003e\u003cp\u003eIntroduce a flexible multi-handpiece facial and body-care station to your spa or beauty studio. This countertop machine features a touchscreen control panel, interchangeable treatment handpieces, contact pads and a vacuum-style treatment-head connection. The images show a selection of multipolar metal-electrode heads, a flat circular head, a ring-style head, a pin-style head, a vented cooling-style head, a suction-associated attachment and rectangular pads. The system is marketed as a nine-in-one configuration for cosmetic face and body services. Exact modes and delivered accessories must be checked against the supplied manual.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e9-in-1 multi-attachment design for a range of professional aesthetic treatments.\u003c\/li\u003e\n\u003cli\u003eFront touchscreen for selecting available functions and adjusting settings.\u003c\/li\u003e\n\u003cli\u003eMultiple metal-electrode handpieces, including three-, four- and six-contact configurations illustrated in the supplier reference.\u003c\/li\u003e\n\u003cli\u003eLarge flat and ring-style handpieces for appropriate manufacturer-designated treatment areas.\u003c\/li\u003e\n\u003cli\u003eRectangular treatment pads and additional accessories shown for compatible modes.\u003c\/li\u003e\n\u003cli\u003eAdjustable suction control on the rear panel (clockwise increases suction and counterclockwise reduces suction, according to the supplier diagram).\u003c\/li\u003e\n\u003cli\u003eWhite and black body with silver-and-black handpieces and side accessory holders.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eUnderstanding the Nine-in-One System\u003c\/h3\u003e\u003cp\u003eThe supplier imagery describes nine handle or accessory configurations. They should not be assumed to represent nine independently validated clinical technologies. The illustrated accessory categories are:\u003c\/p\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRing-style round head:\u003c\/strong\u003e a circular treatment attachment; select its intended mode according to the manufacturer's on-screen instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat metal head:\u003c\/strong\u003e a broad contact attachment for use only with compatible conductive or coupling media specified by the supplier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSix-contact metal head:\u003c\/strong\u003e multipoint electrode attachment intended for areas and settings designated by the operator manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour-contact metal head:\u003c\/strong\u003e smaller multi-electrode attachment for compatible treatment areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree-contact metal head:\u003c\/strong\u003e compact multipoint attachment for precise cosmetic treatment work under the manufacturer's protocol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRectangular light-treatment pad set:\u003c\/strong\u003e illustrated large and smaller pads with indicator markings; the exact light or energy technology must be confirmed before use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin-style treatment head:\u003c\/strong\u003e a larger circular head with multiple contact pins, shown in the accessory photographs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVented cooling-style attachment:\u003c\/strong\u003e cylindrical handpiece with vent openings, whose operating purpose, temperature range and method require manufacturer confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRectangular pulse-pad set:\u003c\/strong\u003e two black-faced rectangular wired pads illustrated separately. Use only with their designated port and confirmed operating mode.\u003c\/li\u003e\n\u003c\/ol\u003e\u003cp\u003e\u003cem\u003eSome illustrations depict overlapping accessories; the above is an image-based overview rather than a verified bill of materials or manufacturer protocol.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eHow to Set Up the Machine\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003eInspect the shipment and verify the included console, all treatment heads, pads, cables, suction parts and any power lead against the packing list.\u003c\/li\u003e\n\u003cli\u003ePosition the equipment upright on a level, dry, ventilated surface away from water.\u003c\/li\u003e\n\u003cli\u003eCheck the rating plate for voltage\/frequency, power requirements and electrical safety markings before connecting to power.\u003c\/li\u003e\n\u003cli\u003eIdentify the exact port for each attachment using the supplier's rear-panel diagram and model-specific manual; do not connect a handpiece to a port simply because the plug appears to fit.\u003c\/li\u003e\n\u003cli\u003eConnect the intended handpiece while power is off. Check cables, connectors, treatment surfaces and pads for signs of damage.\u003c\/li\u003e\n\u003cli\u003eDisinfect reusable contact heads and prepare approved gels, coupling products or accessories as the manufacturer instructs.\u003c\/li\u003e\n\u003cli\u003ePerform a client consultation and check the manufacturer's complete contraindication list for the chosen mode.\u003c\/li\u003e\n\u003cli\u003ePower on and use the touchscreen to choose the handpiece or treatment mode; confirm all required settings before allowing skin contact.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eHow to Use the Multi-Contact and Flat Metal Heads\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003eCleanse the intended face or body treatment region and remove jewelry from the area if instructed by the manufacturer.\u003c\/li\u003e\n\u003cli\u003eIdentify the designated head and mode in the manual. Do not assume all metal heads use the same electrical technology or settings.\u003c\/li\u003e\n\u003cli\u003eApply the prescribed conductive or coupling medium, where required.\u003c\/li\u003e\n\u003cli\u003eStart at the lowest appropriate, manufacturer-approved power and time setting. Check a small treatment area and confirm the client is comfortable.\u003c\/li\u003e\n\u003cli\u003eKeep the head moving continuously if required by the protocol; avoid prolonged stationary contact, skin folds, prominent bones, injured skin and prohibited anatomical sites.\u003c\/li\u003e\n\u003cli\u003eStop immediately if the area becomes painfully hot, unusually red, irritated or uncomfortable.\u003c\/li\u003e\n\u003cli\u003eSwitch off the mode before removing the attachment and gently remove residual product.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eHow to Use the Vacuum\/Suction Accessory\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003eIdentify the correct suction head, rear interface and any required vacuum insert or fitting shown in the manufacturer's diagram.\u003c\/li\u003e\n\u003cli\u003eMake sure all tubing and seals are securely fitted. Do not operate suction with missing or damaged components.\u003c\/li\u003e\n\u003cli\u003eBegin with the suction control at its minimum. The supplied rear-panel illustration indicates clockwise rotation increases suction and counterclockwise rotation decreases it.\u003c\/li\u003e\n\u003cli\u003eTest on a small suitable area with minimal suction and follow the permitted movement, dwell time and anatomical restrictions in the manual.\u003c\/li\u003e\n\u003cli\u003eNever hold strong suction in one spot; stop if bruising, broken capillaries or pain occur.\u003c\/li\u003e\n\u003cli\u003eAt completion, lower suction fully, switch off the mode, remove the head safely, and clean any collection components as instructed.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eHow to Use the Rectangular Pads\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003eDetermine the designated pad type and treatment mode before connecting; the pictured sets may require different electrical ports.\u003c\/li\u003e\n\u003cli\u003eExamine each pad and cable for wear. Use only intact, manufacturer-approved pads and any required conductive medium or protective layer.\u003c\/li\u003e\n\u003cli\u003ePlace pads only on the manufacturer-approved treatment region and follow the placement diagram precisely.\u003c\/li\u003e\n\u003cli\u003eStart at the lowest approved setting, monitor the client's response, and do not exceed specified session times.\u003c\/li\u003e\n\u003cli\u003eDisable the output before moving, disconnecting or cleaning pads. Follow recommended pad replacement and cleaning procedures.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eHow to Use Other Handpieces\u003c\/h3\u003e\u003cp\u003eFor the ring-style head, pin-style circular head and vented attachment, match each tool to the correctly named mode and procedure in the model-specific manual before use. Settings such as temperature, energy type, intensity and treatment duration cannot be safely established from photographs. Never use unverified energy settings or operate any attachment over the eyes, neck structures or sensitive areas unless the manufacturer specifically authorizes the area.\u003c\/p\u003e\u003ch3\u003eExample Professional Treatment Workflow\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConsult:\u003c\/strong\u003e document the intended cosmetic treatment, medical device implants, skin sensitivity and recent procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrepare:\u003c\/strong\u003e cleanse and dry the relevant area, and choose a single suitable handpiece and approved accessory medium.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest:\u003c\/strong\u003e start conservatively with the model's documented settings and check comfort.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTreat:\u003c\/strong\u003e follow the designated motion, contact pattern, approved treatment area and time limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinish:\u003c\/strong\u003e power down the output, remove any remaining medium, and apply suitable moisturizing skincare and SPF for exposed skin during daytime.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean:\u003c\/strong\u003e disinfect contact accessories, inspect cords and return attachments to their holders.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eCleaning and Care\u003c\/h3\u003e\u003cp\u003eSwitch off and unplug before routine cleaning unless the manual specifies otherwise. Never immerse the console, rear panel, connectors or cables. Remove cosmetic residue and clean treatment surfaces with manufacturer-approved materials; fully dry reusable accessories before storage. Disinfect items between clients. Inspect seals, suction components, cooling vents, pad surfaces and handpiece cables before every appointment. Keep air vents unobstructed and arrange servicing according to manufacturer instructions.\u003c\/p\u003e\u003ch3\u003eImportant Safety \u0026amp; Professional-Use Information\u003c\/h3\u003e\u003cp\u003eFor trained operators following the exact device manual. Do not use energy-delivering treatments on people with pacemakers or other implanted electronic devices, or on any client with a contraindication identified by the manufacturer. Screen for pregnancy, implanted metal near the treatment site, sensory impairment, open wounds, active skin infections, recent aggressive procedures and other relevant risk factors. Avoid the eyes, anterior neck, damaged skin and prohibited body areas. Do not use an unidentified port, attachment, treatment setting or unverified electrical mode. Stop immediately for pain, unexpected heat, burns or other adverse reactions. Product images are illustrative and do not establish medical efficacy or guaranteed lifting, slimming or skin-tightening outcomes.\u003c\/p\u003e\u003ch3\u003eProduct Details\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct: multifunctional 9-in-1 professional beauty equipment\u003c\/li\u003e\n\u003cli\u003eUse: cosmetic face and body care with compatible treatment accessories\u003c\/li\u003e\n\u003cli\u003eInterface: touchscreen and rear connection panel\u003c\/li\u003e\n\u003cli\u003eColor: white console with black and silver components\u003c\/li\u003e\n\u003cli\u003eBrand\/store: Beautivana\u003c\/li\u003e\n\u003cli\u003eCountry of origin: China\u003c\/li\u003e\n\u003cli\u003eSKU: BV-9IN1-FB-425\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eImportant: The device's exact nine modalities, whether 'laser' on screen identifies a specific technology, included accessories, electrical rating, energy levels and applicable regulatory approvals have not been verified. Obtain the original manufacturer manual and specifications before professional operation or making technical performance claims.\u003c\/em\u003e\u003c\/p\u003e","brand":"Beautivana","offers":[{"title":"Default Title","offer_id":67663385362707,"sku":"BV-9IN1-FB-425","price":475.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/5477\/3779\/files\/IMG_8032.jpg?v=1792027360","url":"https:\/\/beautivana.com\/products\/beautivana-9-in-1-professional-face-body-beauty-system-multifunctional-spa-machine","provider":"Beautivana","version":"1.0","type":"link"}