Beautivana 9-in-1 Professional Face & Body Beauty System
Introduce a flexible multi-handpiece facial and body-care station to your spa or beauty studio. This countertop machine features a touchscreen control panel, interchangeable treatment handpieces, contact pads and a vacuum-style treatment-head connection. The images show a selection of multipolar metal-electrode heads, a flat circular head, a ring-style head, a pin-style head, a vented cooling-style head, a suction-associated attachment and rectangular pads. The system is marketed as a nine-in-one configuration for cosmetic face and body services. Exact modes and delivered accessories must be checked against the supplied manual.
Highlights
- 9-in-1 multi-attachment design for a range of professional aesthetic treatments.
- Front touchscreen for selecting available functions and adjusting settings.
- Multiple metal-electrode handpieces, including three-, four- and six-contact configurations illustrated in the supplier reference.
- Large flat and ring-style handpieces for appropriate manufacturer-designated treatment areas.
- Rectangular treatment pads and additional accessories shown for compatible modes.
- Adjustable suction control on the rear panel (clockwise increases suction and counterclockwise reduces suction, according to the supplier diagram).
- White and black body with silver-and-black handpieces and side accessory holders.
Understanding the Nine-in-One System
The supplier imagery describes nine handle or accessory configurations. They should not be assumed to represent nine independently validated clinical technologies. The illustrated accessory categories are:
-
Ring-style round head: a circular treatment attachment; select its intended mode according to the manufacturer's on-screen instructions.
-
Flat metal head: a broad contact attachment for use only with compatible conductive or coupling media specified by the supplier.
-
Six-contact metal head: multipoint electrode attachment intended for areas and settings designated by the operator manual.
-
Four-contact metal head: smaller multi-electrode attachment for compatible treatment areas.
-
Three-contact metal head: compact multipoint attachment for precise cosmetic treatment work under the manufacturer's protocol.
-
Rectangular light-treatment pad set: illustrated large and smaller pads with indicator markings; the exact light or energy technology must be confirmed before use.
-
Pin-style treatment head: a larger circular head with multiple contact pins, shown in the accessory photographs.
-
Vented cooling-style attachment: cylindrical handpiece with vent openings, whose operating purpose, temperature range and method require manufacturer confirmation.
-
Rectangular pulse-pad set: two black-faced rectangular wired pads illustrated separately. Use only with their designated port and confirmed operating mode.
Some illustrations depict overlapping accessories; the above is an image-based overview rather than a verified bill of materials or manufacturer protocol.
How to Set Up the Machine
- Inspect the shipment and verify the included console, all treatment heads, pads, cables, suction parts and any power lead against the packing list.
- Position the equipment upright on a level, dry, ventilated surface away from water.
- Check the rating plate for voltage/frequency, power requirements and electrical safety markings before connecting to power.
- Identify the exact port for each attachment using the supplier's rear-panel diagram and model-specific manual; do not connect a handpiece to a port simply because the plug appears to fit.
- Connect the intended handpiece while power is off. Check cables, connectors, treatment surfaces and pads for signs of damage.
- Disinfect reusable contact heads and prepare approved gels, coupling products or accessories as the manufacturer instructs.
- Perform a client consultation and check the manufacturer's complete contraindication list for the chosen mode.
- Power on and use the touchscreen to choose the handpiece or treatment mode; confirm all required settings before allowing skin contact.
How to Use the Multi-Contact and Flat Metal Heads
- Cleanse the intended face or body treatment region and remove jewelry from the area if instructed by the manufacturer.
- Identify the designated head and mode in the manual. Do not assume all metal heads use the same electrical technology or settings.
- Apply the prescribed conductive or coupling medium, where required.
- Start at the lowest appropriate, manufacturer-approved power and time setting. Check a small treatment area and confirm the client is comfortable.
- Keep the head moving continuously if required by the protocol; avoid prolonged stationary contact, skin folds, prominent bones, injured skin and prohibited anatomical sites.
- Stop immediately if the area becomes painfully hot, unusually red, irritated or uncomfortable.
- Switch off the mode before removing the attachment and gently remove residual product.
How to Use the Vacuum/Suction Accessory
- Identify the correct suction head, rear interface and any required vacuum insert or fitting shown in the manufacturer's diagram.
- Make sure all tubing and seals are securely fitted. Do not operate suction with missing or damaged components.
- Begin with the suction control at its minimum. The supplied rear-panel illustration indicates clockwise rotation increases suction and counterclockwise rotation decreases it.
- Test on a small suitable area with minimal suction and follow the permitted movement, dwell time and anatomical restrictions in the manual.
- Never hold strong suction in one spot; stop if bruising, broken capillaries or pain occur.
- At completion, lower suction fully, switch off the mode, remove the head safely, and clean any collection components as instructed.
How to Use the Rectangular Pads
- Determine the designated pad type and treatment mode before connecting; the pictured sets may require different electrical ports.
- Examine each pad and cable for wear. Use only intact, manufacturer-approved pads and any required conductive medium or protective layer.
- Place pads only on the manufacturer-approved treatment region and follow the placement diagram precisely.
- Start at the lowest approved setting, monitor the client's response, and do not exceed specified session times.
- Disable the output before moving, disconnecting or cleaning pads. Follow recommended pad replacement and cleaning procedures.
How to Use Other Handpieces
For the ring-style head, pin-style circular head and vented attachment, match each tool to the correctly named mode and procedure in the model-specific manual before use. Settings such as temperature, energy type, intensity and treatment duration cannot be safely established from photographs. Never use unverified energy settings or operate any attachment over the eyes, neck structures or sensitive areas unless the manufacturer specifically authorizes the area.
Example Professional Treatment Workflow
-
Consult: document the intended cosmetic treatment, medical device implants, skin sensitivity and recent procedures.
-
Prepare: cleanse and dry the relevant area, and choose a single suitable handpiece and approved accessory medium.
-
Test: start conservatively with the model's documented settings and check comfort.
-
Treat: follow the designated motion, contact pattern, approved treatment area and time limit.
-
Finish: power down the output, remove any remaining medium, and apply suitable moisturizing skincare and SPF for exposed skin during daytime.
-
Clean: disinfect contact accessories, inspect cords and return attachments to their holders.
Cleaning and Care
Switch off and unplug before routine cleaning unless the manual specifies otherwise. Never immerse the console, rear panel, connectors or cables. Remove cosmetic residue and clean treatment surfaces with manufacturer-approved materials; fully dry reusable accessories before storage. Disinfect items between clients. Inspect seals, suction components, cooling vents, pad surfaces and handpiece cables before every appointment. Keep air vents unobstructed and arrange servicing according to manufacturer instructions.
Important Safety & Professional-Use Information
For trained operators following the exact device manual. Do not use energy-delivering treatments on people with pacemakers or other implanted electronic devices, or on any client with a contraindication identified by the manufacturer. Screen for pregnancy, implanted metal near the treatment site, sensory impairment, open wounds, active skin infections, recent aggressive procedures and other relevant risk factors. Avoid the eyes, anterior neck, damaged skin and prohibited body areas. Do not use an unidentified port, attachment, treatment setting or unverified electrical mode. Stop immediately for pain, unexpected heat, burns or other adverse reactions. Product images are illustrative and do not establish medical efficacy or guaranteed lifting, slimming or skin-tightening outcomes.
Product Details
- Product: multifunctional 9-in-1 professional beauty equipment
- Use: cosmetic face and body care with compatible treatment accessories
- Interface: touchscreen and rear connection panel
- Color: white console with black and silver components
- Brand/store: Beautivana
- Country of origin: China
- SKU: BV-9IN1-FB-425
Important: The device's exact nine modalities, whether 'laser' on screen identifies a specific technology, included accessories, electrical rating, energy levels and applicable regulatory approvals have not been verified. Obtain the original manufacturer manual and specifications before professional operation or making technical performance claims.